High Voltage Tan Delta Test Equipment for Transformer Bushing, Capacitor and Surge Arrester Insulation Measurement

High Voltage Tan Delta Test Equipment for Transformer Bushing, Capacitor and Surge Arrester Insulation Measurement

Product Details:
Place of Origin: China
Brand Name: Sansion Power
Certification: CE/SGS/EMS/ISO 9001
Model Number: SXJS-III
Detail Information
Place of Origin:
China
Brand Name:
Sansion Power
Certification:
CE/SGS/EMS/ISO 9001
Model Number:
SXJS-III
Test Voltage:
0.5–10 KV
Test Frequency:
45 Hz / 55 Hz
Capacitance Measurement:
3 PF–60000 PF
Cx Measurement Accuracy:
±(Reading * 1% + 1 PF)
Tan Delta Accuracy:
±(Reading * 1% + 0.00040)
Test Power Technology:
Variable-Frequency Power Supply
Highlight:

High Light

Highlight:

High Voltage Tan Delta Test Equipment

,

Transformer Bushing Insulation Measurement

,

Capacitor Surge Arrester Tester

Trading Information
Minimum Order Quantity:
1
Packaging Details:
Plywood Case
Delivery Time:
30 Working Days
Payment Terms:
L/C,T/T
Product Description

Product Description

SXJS-III Tan Delta Tester

The High Voltage Tan Delta Tester is intended for dielectric loss testing of insulation systems in high-voltage electrical equipment. It is applicable to transformers, instrument transformers, bushings, capacitors and surge arresters, covering routine insulation assessment needs in substations, power generation facilities, transformer factories and electrical service departments. It can also be used during installation, commissioning and preventive maintenance.

The instrument adopts a variable-frequency testing method and integrates automatic frequency conversion, analog-to-digital conversion and digital data calculation. Its power source delivers 45 Hz and 55 Hz pure sine waves and can automatically apply test voltage up to 10 kV. With a capacitance measurement range of 3 pF to 60000 pF, it provides a practical solution for field dielectric loss testing where strong electromagnetic interference may be present.

Product Parameters

Parameter Specification
Product Name Tan Delta Tester
Test Voltage 0.5–10 kV
Test Frequency 45 Hz / 55 Hz
Capacitance Measurement 3 pF–60000 pF
Cx Measurement Accuracy ±(Reading * 1% + 1 pF)
Tan Delta Measurement Accuracy ±(Reading * 1% + 0.00040)
Voltage Application Automatic
Test Power Technology Variable-Frequency Power Supply

Product Advantages

  • High-Voltage Insulation Testing — Provides up to 10 kV test voltage for dielectric loss measurement of applicable high-voltage equipment.
  • Anti-Interference Design — Variable-frequency testing technology is suitable for measurement in environments with significant electrical interference.
  • Broad Capacitance Range — Measures capacitance from 3 pF to 60000 pF for different insulation testing applications.
  • Simple Test Operation — Automatic frequency conversion, voltage application and digital calculation help streamline the measurement process.

Application Scenarios

  1. High-voltage transformer insulation testing
  2. Bushing dielectric loss measurement
  3. Capacitor insulation testing
  4. Surge arrester condition testing
  5. Substation field dielectric loss measurement
  6. Power equipment preventive testing

FAQ

Q1. Is this instrument suitable for high-voltage electrical equipment?
A: Yes. It is designed for dielectric loss testing of transformers, instrument transformers, bushings, capacitors and surge arresters.

Q2. What is the maximum test voltage?
A: The specified voltage setting range is 0.5–10 kV.

Q3. Does the instrument automatically change the test frequency?
A: Yes. The system uses electronic frequency conversion and provides 45 Hz and 55 Hz pure sine-wave output.

Q4. Is it suitable for on-site substation testing?
A: Yes. It is intended for field dielectric loss measurements, including environments with strong electrical interference.

Q5. What capacitance range can be measured?
A: The specified capacitance measurement range is 3 pF–60000 pF.