Home > Products >
Impulse Voltage Generator
>
Switching Impulse Voltage Generator and High Voltage Test System for Power Transformer and GIS Insulation Testing

Switching Impulse Voltage Generator and High Voltage Test System for Power Transformer and GIS Insulation Testing

Product Details:
Place of Origin: China
Brand Name: Sansion
Certification: CE SGS ISO9001
Model Number: SXCY
Detail Information
Place of Origin:
China
Brand Name:
Sansion
Certification:
CE SGS ISO9001
Model Number:
SXCY
Impulse Capacitance:
0.0278μF ~ 0.5μF
Impulse Energy:
7.31kJ ~ 320kJ
Stage Voltage:
±100kV ~ ±200kV
Rated Voltage:
±100kV ~ ±4800kV
Waveform Type:
Full-wave, Chopped-wave, Switching Impulse
Number Of Stages:
1 ~ 24
Stage Capacitance:
0.325μF ~ 1μF
Measurement System:
Integrated Digital Waveform Measurement And Control
Highlight:

High Light

Highlight:

Impulse Voltage Generator for Power Transformer

,

High Voltage Test System for GIS Insulation

,

Switching Impulse Voltage Generator Testing

Trading Information
Minimum Order Quantity:
1
Packaging Details:
plywood case
Delivery Time:
30 work days
Payment Terms:
T/T,L/C
Product Description
Product Overview

A Switching Impulse Voltage Generator is engineered to produce standardized switching impulse waveforms for evaluating the insulation performance of high-voltage electrical equipment under switching overvoltage conditions.
Switching impulse testing is an important dielectric testing method for certain high-voltage insulation applications, particularly in power transmission and extra-high-voltage electrical equipment.
The system can be engineered according to the required voltage level, impulse energy, waveform parameters, and test object specifications. Depending on the project configuration, it can incorporate impulse generation, voltage measurement, digital waveform recording, and computerized control functions.

Main Testing Functions
  • Switching impulse voltage generation
  • Switching impulse withstand testing
  • Standard lightning impulse testing, where supported
  • High-voltage waveform measurement
  • Digital waveform acquisition
  • Waveform parameter evaluation
  • Test data recording and analysis
Typical Applications
  • High-voltage power transformers
  • Extra-high-voltage transmission equipment
  • GIS testing laboratories
  • High-voltage insulation testing facilities
  • Electrical equipment type-test laboratories
  • Power industry research institutions
Main System Components
  • Switching impulse voltage generator
  • High-voltage charging unit
  • Voltage divider
  • Digital measuring system
  • Computerized control unit
  • Waveform acquisition and analysis software
  • Auxiliary high-voltage components
Key Technical Considerations

When selecting a switching impulse voltage generator, buyers should consider the following factors:

  • Required switching impulse voltage
  • Standard waveform parameters
  • Impulse energy capacity
  • Test object characteristics
  • Voltage divider performance
  • Measuring system requirements
  • Applicable testing standards
  • Laboratory dimensions and installation conditions
Main Customer Concerns
  • Waveform RequirementsThe system must be capable of generating the switching impulse waveform required by the applicable test specification.
  • Testing Voltage and EnergyThe generator must have sufficient capacity for the intended test objects.
  • Measurement PerformanceAccurate waveform acquisition and analysis are essential for reliable test evaluation.
  • System CompatibilityThe generator, measuring equipment, control system, and auxiliary components must work together as an integrated testing solution.
  • Customized ConfigurationDifferent testing laboratories may require different voltage levels, energy capacities, and system arrangements.
Frequently Asked Questions
Q1: What is switching impulse testing?

It evaluates the insulation withstand performance of electrical equipment under transient overvoltages associated with switching operations.

Q2: What is the difference between lightning impulse and switching impulse?

They represent different transient overvoltage conditions and use different standardized waveform parameters.

Q3: Can one system perform both lightning and switching impulse tests?

Some impulse testing systems can be configured for both functions. This must be confirmed according to the technical specification.

Q4: Is switching impulse testing necessary for all transformers?

No. Testing requirements depend on transformer design, rated voltage, applicable standards, and project specifications.

Q5: Can the system be customized for extra-high-voltage testing applications?

Yes. System capacity and configuration can be evaluated according to the required test voltage, energy, waveform, and test object.

Q6: What information is required for a quotation?

Please provide the test object, required switching impulse voltage, waveform parameters, applicable standards, and laboratory installation conditions.

Contact Our Engineering Team
Looking for a switching impulse voltage generator for transformer or high-voltage insulation testing?

Send us your technical requirements to receive a customized system configuration and proposal.

Lightning impulse testing equipment setup for high-voltage GIS, switchgear, bushings, circuit breakers, and electrical insulators in a test laboratory

Lightning impulse testing equipment setup for high-voltage GIS, switchgear, bushings, circuit breakers, and electrical insulators in a test laboratory.