| Chopping gap for precise cut-wave tests | Shunt resistor for accurate current waveform recording |
| 1 | Impulse voltage grade | 100kV-7200kV |
| 2 | Standard lightning wave | 1.2±30%/50±20%µS |
| 3 | Peak oscillation | 5% |
| 4 | Standard switching wave | 250±20%/2500±60%µS |
| 5 | Virtual front time of oscillating lightning wave | 15µS |
| 6 | Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave | 15µS-1µS |
| 7 | Minimum output voltage | 10%Un |
| 8 | Charging voltage instability | 1% |
| 9 | Synchronizing range | 20% |
| 10 | Synchronous discharge error rate | 2% |
| 11 | Ignition range | 10%-100% |
| 12 | Working time | 70%UN Discontinuous work (charge-discharge 300s/time) 70%nn Continuous work (charge-discharge 120s/time) |
| 13 | Generator efficiency | Lightning wave (no load) - 90% |
| 14 | Time to chopping | 2-5µS |