Digital Grounding Grid Resistance Tester Cable Test Equipment for Power Stations, Substations and Electrical Grounding System Testing

Digital Grounding Grid Resistance Tester Cable Test Equipment for Power Stations, Substations and Electrical Grounding System Testing

Product Details:
Place of Origin: China
Brand Name: Sansion
Certification: CE SGS ISO9001
Model Number: SXDW
Detail Information
Place of Origin:
China
Brand Name:
Sansion
Certification:
CE SGS ISO9001
Model Number:
SXDW
Output Current:
2A, 4A, 6A, 8A, 10A Adjustable
Test Method:
Standard 4-pole
Power Input:
AC 220V±10%, 50/60Hz
Measurement Error:
±(2% Reading + 0.005Ω)
Resolution:
0.001Ω
Impedance Range:
0-200Ω, Up To 5000Ω Custom
Highlight:

High Light

Highlight:

Digital Grounding Grid Resistance Tester

,

Cable Test Equipment for Substations

,

Electrical Grounding System Testing Equipment

Trading Information
Minimum Order Quantity:
1
Packaging Details:
plywood case
Delivery Time:
30 work days
Payment Terms:
T/T,L/C
Product Description

Product Introduction

The SXDW-10A Large Ground Grid Resistance & Impedance Tester is specially developed for testing large-scale grounding systems where conventional earth resistance measurement methods may be affected by strong electrical interference.
Equipped with variable-frequency measurement technology and a maximum output current of 10A, the SXDW-10A provides a practical solution for measuring grounding impedance, earth resistance, interconnection resistance and soil resistivity.

Technical Highlights

1. 10A Maximum Test Current
Five selectable output current levels provide flexibility for different grounding system conditions.
2. Maximum output current: 10A.
0.001Ω Measurement Resolution
Designed for low-impedance grounding applications, the instrument provides a resolution of 0.001Ω.
3. 45Hz / 55Hz Dual-Frequency Technology
Reduces the influence of 50Hz power-frequency interference and improves the reliability of field measurements.
4. 0–200Ω Standard Measurement Range
Covers a broad range of grounding resistance and impedance measurement requirements. An extended range of up to 5000Ω can be customized.
5. Automatic Measurement
Automatic measurement simplifies field operation and helps reduce manual testing procedures.
6. Built-in Thermal Printer
Print measurement results directly at the test site for convenient record keeping.
7. Flexible Field Power Supply
Supports AC 220V input and can operate with either mains electricity or a generator.
8. Optional Communication and Language Configuration
RS-232 communication is available as an option. Bluetooth is available for the color-screen version. An English-language version can also be customized.

Application

- Substation Grounding Grid TestingSuitable for grounding grid testing in substations of various voltage levels.
It can be used to measure grounding impedance and resistance, supporting grounding system inspection and evaluation. 

- Power Plant Grounding SystemsProvides grounding impedance and resistance measurement capabilities for power plant grounding networks.
Its high-current output and variable-frequency technology are suitable for field measurement in complex electrical environments.

- Microwave Communication StationsApplicable to grounding resistance testing at microwave stations and communication facilities. 

- Lightning Protection GroundingCan be used for grounding resistance testing of lightning protection installations, including lightning rods. 

- Industrial Grounding NetworksSuitable for industrial electrical facilities requiring grounding resistance, impedance or soil resistivity measurements.

- Electrical Testing and Maintenance OrganizationsA practical instrument for electrical testing companies, power engineering contractors, inspection organizations and maintenance teams performing grounding system measurements.

FAQ

Q1. What makes the SXDW-10A different from a conventional earth resistance tester?
The SXDW-10A is developed specifically for large grounding grid applications. It combines high-current output up to 10A, variable-frequency anti-interference technology and multiple grounding measurement functions.
It is intended for complex grounding networks in substations and power plants rather than only individual earth electrode testing.

Q2. Why is a high test current important for large ground grids?
Large grounding systems may have very low impedance. A higher test current helps establish a stronger measurement signal relative to external interference.
The SXDW-10A provides selectable current levels up to 10A for different field testing requirements.

Q3. Why does the instrument use 45Hz and 55Hz instead of only 50Hz?
The normal operating frequency of many power networks is 50Hz. Measuring at 45Hz and 55Hz helps separate the injected test signal from background power-frequency interference.
This approach improves the reliability of grounding measurements in electrically noisy environments.

Q4. Can the SXDW-10A test a substation without interrupting power supply?
The instrument is designed with strong anti-interference capability.
However, actual feasibility depends on the grounding arrangement, site conditions and applicable safety procedures. A site-specific testing plan should be prepared before measurement.

Q5. What is the maximum output current?
The maximum output current is 10A. Users can select 2A, 4A, 6A, 8A or 10A according to testing requirements.

Digital Grounding Grid Resistance Tester  Cable Test Equipment for Power Stations, Substations and Electrical Grounding System Testing