Home > Products >
Transformer Test Equipment
>
Transformer DC Resistance Tester High Accuracy Transformer Winding Resistance Test Set with Automatic Current Selection, Three Phase Measurement and Demagnetization Function

Transformer DC Resistance Tester High Accuracy Transformer Winding Resistance Test Set with Automatic Current Selection, Three Phase Measurement and Demagnetization Function

Product Details:
Place of Origin: China
Brand Name: Sansion
Certification: CE/CNAS/ISO9001
Model Number: SXZR
Detail Information
Place of Origin:
China
Brand Name:
Sansion
Certification:
CE/CNAS/ISO9001
Model Number:
SXZR
Measurement Type:
DC Resistance
Current Output:
Multiple Ranges
Current Selection:
Automatic
Phase Measurement:
Three-Phase Simultaneous
Display Type:
Digital
Data Interface:
USB / RS232 / RS485
Demagnetization:
Automatic
Protection Functions:
Overcurrent, Open-Circuit, Back-EMF, Discharge
Highlight:

High Light

Highlight:

Transformer DC Resistance Tester with Automatic Current Selection

,

Transformer Winding Resistance Test Set with Three Phase Measurement

,

Transformer DC Resistance Tester with Demagnetization Function

Trading Information
Minimum Order Quantity:
1 Set
Packaging Details:
Plywood Case
Delivery Time:
30 work days
Payment Terms:
L/C T/T
Supply Ability:
100 Units/Month
Product Description
Product Overview

A Transformer DC Resistance Tester is an essential instrument for measuring the DC resistance of transformer windings. It helps manufacturers and electrical testing engineers evaluate winding connections, conductor integrity and contact conditions.

By injecting a stable DC current into the transformer winding and measuring the corresponding voltage drop, the instrument calculates the winding resistance with high resolution and accuracy.

This testing process helps identify potential problems such as poor welding connections, loose contacts, damaged conductors and abnormal tap changer contact resistance.

Designed for transformer manufacturing, installation, commissioning and preventive maintenance, this instrument provides a convenient solution for routine transformer winding resistance measurement.

Main Testing Functions
  • DC Resistance Measurement: Measures the DC resistance of transformer high-voltage and low-voltage windings.
  • Multiple Current Output: Provides different test current ranges to accommodate various transformer capacities and resistance values.
  • Automatic Current Selection: Automatically selects an appropriate test current according to the measurement requirements, where supported.
  • Three-Phase Measurement: Supports simultaneous three-phase winding resistance measurement on compatible transformer connections.
  • Resistance Unbalance Calculation: Automatically calculates the three-phase resistance unbalance rate.
  • Temperature Conversion: Converts resistance readings to a reference temperature according to selected winding material and temperature coefficients.
  • Automatic Demagnetization: Helps reduce residual magnetism in the transformer core after testing.
  • Data Storage: Stores test results for later review and comparison.
  • Data Export: Supports USB or communication interfaces depending on the model.
  • Safety Protection: May include overcurrent, open-circuit, back-EMF and discharge protection.
Typical Applications
  • Power transformer manufacturing and factory inspection.
  • Distribution transformer production.
  • Transformer installation and commissioning.
  • Substation preventive maintenance.
  • Transformer overhaul and repair.
  • Power plant electrical maintenance.
  • Third-party transformer testing laboratories.
  • Electrical engineering and commissioning companies.
Problems This Equipment Helps Solve
1. Abnormal Winding Resistance

Different resistance values between phases may indicate connection problems, winding defects or abnormal contact conditions.

2. Poor Welding and Connection Quality

Resistance measurements help identify abnormal resistance at winding joints and electrical connections.

3. Tap Changer Contact Problems

Abnormal resistance measurements across tap positions may help identify poor contact conditions in tap changer circuits.

4. Time-Consuming Manual Testing

Three-phase simultaneous measurement can reduce repeated wiring and measurement operations when supported by the instrument.

5. Inconsistent Historical Test Records

Temperature conversion and data storage help engineers compare measurements under more consistent conditions.

Frequently Asked Questions
Q1: What is a transformer DC resistance tester used for?

It measures transformer winding DC resistance to evaluate winding connections, conductor continuity and contact conditions.

Q2: Why is DC resistance testing important for transformers?

It helps identify abnormal winding resistance, poor electrical connections, damaged conductors and tap changer contact problems.

Q3: Can the instrument test both high-voltage and low-voltage windings?

Yes. The appropriate current range and connection method can be selected according to the winding resistance and transformer specifications.

Q4: Does it support three-phase simultaneous testing?

Three-phase simultaneous measurement is available on compatible models. Please confirm the supported winding connections and measurement modes.

Q5: Why is automatic demagnetization important?

DC testing can leave residual magnetism in the transformer core. Demagnetization helps reduce this residual magnetism before subsequent operations or tests.

Q6: Can the instrument automatically select the test current?

Some models provide automatic current selection to simplify operation and improve measurement efficiency.

Q7: Can test data be exported to a computer?

Depending on the model, data can be transferred through USB, RS232, RS485 or other supported communication interfaces.

Q8: How do I choose the correct test current?

The selection depends on winding resistance, transformer capacity, test requirements and instrument specifications.

Request a Technical Quotation

Please provide the transformer rated capacity, voltage level, required maximum test current and preferred measurement functions to receive a suitable equipment recommendation.

Transformer DC resistance tester instrument for measuring transformer winding resistance with automatic current selection and three-phase measurement