AC Dielectric Withstand Testing System Rated 150kV 10kVA for Pre-Commissioning and Acceptance Inspection of Transformers and High Voltage Electrical Equipment

AC Dielectric Withstand Testing System Rated 150kV 10kVA for Pre-Commissioning and Acceptance Inspection of Transformers and High Voltage Electrical Equipment

Product Details:
Place of Origin: China
Brand Name: Sansion Power
Certification: CE/SGS/EMS/ISO 9001
Model Number: YDW
Detail Information
Place of Origin:
China
Brand Name:
Sansion Power
Certification:
CE/SGS/EMS/ISO 9001
Model Number:
YDW
Capacity:
10 KVA
AC Test Voltage:
150 KV
Test Category:
Power Frequency AC Withstand
Transformer Type:
PD-Free Test Transformer
Operation System:
Motorized Console
Measurement System:
Voltage Divider
Highlight:

High Light

Highlight:

150kV dielectric withstand tester

,

10kVA transformer testing system

,

high voltage equipment inspection tester

Trading Information
Minimum Order Quantity:
1
Packaging Details:
Plywood Case
Delivery Time:
30 Working Days
Payment Terms:
L/C,T/T
Product Description
Product Description

Product Name: 10kVA/150kV Power Frequency PD-Free AC Withstand Test System

Before electrical equipment is accepted or put into service, insulation performance must be verified against the required AC withstand level. The 10kVA/150kV Power Frequency PD-Free AC Withstand Test System provides a dedicated high-voltage testing solution for acceptance, commissioning and insulation verification procedures.

The equipment is centered around a 150kV PD-Free Test Transformer and supported by a Motorized Operation Console, Power Supply and Voltage Divider. During a test, the operator can progressively apply the required power-frequency AC voltage and monitor the corresponding high-voltage level. The PD-free configuration is especially useful when minimizing test-source discharge is an important part of the testing environment.

Product Parameters
Parameter Specification
Capacity 10 kVA
AC Test Voltage 150 kV
Test Category Power Frequency AC Withstand
Transformer PD-Free Test Transformer
Operation System Motorized Console
Measurement System Voltage Divider
Primary Function Dielectric Withstand Verification
Product Advantages
  • Acceptance-Test Ready: Suitable for insulation verification during equipment acceptance and commissioning procedures.
  • Controlled Voltage Application: Supports progressive application of AC test voltage.
  • PD-Free Configuration: Helps maintain low background discharge from the test source.
  • Versatile Testing Platform: Can be applied to suitable transformers and other high-voltage electrical equipment.
Application Scenarios
  • Pre-commissioning electrical tests
  • Equipment acceptance inspection
  • Transformer insulation verification
  • Substation equipment testing
  • Electrical installation commissioning
  • Maintenance and service testing
FAQ

Q1: Can the system be used for acceptance testing?
A: Yes. It can be used for applicable power-frequency AC withstand tests during equipment acceptance and commissioning.

Q2: What type of transformer is included?
A: The system uses a PD-Free Test Transformer specifically configured for the testing system.

Q3: What is the system capacity?
A: The rated capacity is 10kVA, with a maximum AC test voltage of 150kV.

Q4: What equipment can be tested?
A: Suitable transformers and other electrical equipment requiring power-frequency AC dielectric withstand testing can be tested according to their applicable test requirements.

AC Dielectric Withstand Testing System Rated 150kV 10kVA for Pre-Commissioning and Acceptance Inspection of Transformers and High Voltage Electrical Equipment