Home > Products >
AC Resonant Test System
>
6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing

6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing

Product Details:
Place of Origin: China
Brand Name: Sansion
Certification: CE SGS ISO9001
Model Number: SXBP
Detail Information
Place of Origin:
China
Brand Name:
Sansion
Certification:
CE SGS ISO9001
Model Number:
SXBP
Max Diameter Of Workpiece:
900mm
Mass Scope Of Workpiece:
<900kg
Type:
Strength Testing Machine
Maxcapacity:
<1000KN
Accuracy Grade:
0.5
Load Way:
Electronic Load
Loading Method:
Static Load
Display:
LCD Display
Control:
Computer Control
Weight:
0-100Kg
Trading Information
Minimum Order Quantity:
1
Price:
1000
Packaging Details:
plywood case
Product Description
Advantage
  1. Placed way: the placement of variable frequency power for longitudinal and transverse, especially suitable for field operation and observe.
  2. Shockproof protection: internal and external have special damping rubber support foot and protect aluminum boxes, which can effectively slow motion and lifting the bumpy transport the shock. Ensure the inverter power long-term stability and reliability.
  3. Parameter display: touch or external mouse LCD interface display system.

    Can show resonance voltage (namely test before setting goals voltage), test frequency, measure frequency, low-pressure voltage, low voltage electric current, voltage time, over-voltage protection, over-current protection, flash winding protection, phase booster and stage timing, operation mode switch, capacitor, inductance, frequency swap calculation, parameters, still can show inquiry on frequency curve, voltage curve can intuitivey judgment when trials resonance frequency accurately and stability.

  4. Parameter Settings: big screen touch LCD backlit and external mouse directly in completing various parameters Settings. But on the initial frequency, termination frequency, starting voltage, phase booster and timing, measuring bleeder variable ratio, incentive change ratio, over-voltage protection, over-current protection, flash winding protection, test mode, capacitance inductance frequency swap calculation, parameter setting tips, and help parameters Settings or choice.
  5. Test mode: touch screen and external mouse operation, there is automatic and semi-automatic, manual three operating status. With pressor, tuning (including manual, automatic), subsection pressurized and timing, running status, pattern switching, troubleshooting tips, capacitance inductance frequency swap computing functions, etc.
  6. Protection function and information clew: having high-pressure over-voltage protection, low-pressure over-current, over-current protection, as well as detuning protection, zero, shem winding protection, emergency stop, undervoltage protection multiple protection function.
  7. Automatic voltage function: system according to the test voltage or manually set of automatic tracking and boost results, stable test voltage, voltage stability can amount to 1.0%.
  8. FM range and frequency resolution all can set: FM range set:30~300Hz,45~100Hz,200-300Hz, on-demand setting, can accelerate tuning process; The frequency resolution, according to the needs, presetting 0.1 Hz, efficiency and tuned in tuned balance between accuracy obtained optimization.
  9. Frequency adjustment is divided into thick harmonic fine tuning, and automatic resonant point, guarantee for trials in the whole experiment resonant frequency process does not happen drift.
  10. Storage measuring datas and print.10kV/35KV Power transformers, GIS Breakers,Transformer,insulators, busbar AC withstand voltage testing.
Parameters of Full System
  • Rated Capacity: 6000kVA;
  • Output Voltage: 0-750KV;
  • Output frequency: 30-300Hz;
  • Input Power: 220V/380V ±10 % single phase, 50Hz;
  • Waveform distortion rate: output voltage distortion ≤ 1%;
  • Working time: 30mins under rated load;
  • Cable testing: continuous 60 minutes under rated load;
  • Temperature rise: ≤65K under rated load;
  • Working Temperature: -15ºC~+45ºC;
  • Quality factors: Q ≥ 50;
  • Cable testing Q ≥ 30 (depend on load);
  • Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;
  • Accuracy: RMS 1.5.
Application & System configuration

10kV/35KV Power transformers, GIS Breakers,Transformer,insulators, busbar AC withstand voltage testing.

FAQ

1.Is your company a sales company or a manufacturer?

Sansion Power Electric Co., Ltd. is an industrial and trade enterprise with its own factory, self-produced and self-sold. Founded in 2005, we have twenty years of production experience with reliable production lines, test rooms, and R&D centers.

2.Are goods in stock, can they be customized, and what is the delivery time?

Goods are made to order according to customer requirements using the latest technology. Delivery time is typically within 10 working days.

3.Is the quality guaranteed?

We use imported components and conduct three quality inspections before shipment. Export products are packed in non-fumigation wooden boxes.

4.What are the after-sales terms?

We offer free consulting service, one year warranty, and support through email communication, video calls, and on-site technical assistance to resolve after-sales problems promptly.

5.What are the cooperative countries or regions?

Products exported to United States, France, Brazil, Australia, Spain, Portugal, Oman, Russia, Netherlands, Indonesia, Bangladesh, Saudi Arabia, Chile, Colombia, Panama, Malaysia and other countries.

About Sansion

Established in 2005, Sansion Power Electric comprises technical experts with over 20 years of experience in R&D, manufacturing, and marketing of power electrical testing products. Our solutions are widely applied across power electric, railroad, energy conservation and environment protection, water conservancy, petrochemical industry, aerospace, and other sectors.

Sansion Power Electric includes R&D department, instruments manufacturing workshop, HV workshop, sample exhibition room, HV testing laboratory, quality control department, general office, sales departments, and information office. We currently employ over 80 staff members, including 20 technical engineers.

We have obtained ISO9001 quality system certification, and all products strictly conform to international IEC and Chinese state standards.

6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing 0 6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing 1 6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing 2 6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing 3 6000kVA 750kV Variable Frequency Series Resonance Hipot Test Device with Computer Control for AC Withstand Voltage Testing 4