Casa > produtos >
Gerador de tensão de impulso
>
500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing

500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing

Detalhes do produto:
Lugar de origem: China
Marca: Sansion
Certificação: CE SGS ISO9001
Informações detalhadas
Lugar de origem:
China
Marca:
Sansion
Certificação:
CE SGS ISO9001
Modelo NÃO.:
SXCF
Max Diameter do Workpiece:
900mm
Espaço maciço do Workpiece:
<900kg
Tipo:
Máquina de ensaio de resistência
Capacidade máxima:
< 1000KN
Grau de precisão:
0,5
Maneira da carga:
Carga eletrônica
Método de carregamento:
Carga dinâmica
Mostrar:
Visor LCD
Controlar:
Controle de computador
peso:
0-100kg
fonte de energia:
AC380V
Posição do cilindro do óleo:
Sob
Pacote de Transporte:
Caixa de madeira compensada
Especificação:
1000mm*600mm*560mm
Marca registrada:
Sansão
Origem:
China
Código HS:
9030339000
Capacidade de produção:
100 unidades/mês
Vantagem1:
Tensão nominal 500kV
Advantage2:
Energia 1kJ
Vantagem3:
Para transformador, reator, teste de cabo
Advantage4:
Padrão de forma de onda de impulso relâmpago
Vantagem5:
Alta estabilidade e confiabilidade
Vantagem6:
Controle Totalmente Automático
Vantagem7:
Estrutura compacta
Vantagem8:
Estrutura compacta
Vantagem9:
Fácil operação e manutenção
Vantagem10:
Cumprir com o padrão IEC
Trading Information
Quantidade de ordem mínima:
1
Preço:
1000
Detalhes da embalagem:
Caixa de madeira compensada
Termos de pagamento:
T/T,L/C
Descrição do produto
Lightning Impulse Voltage Generator
Product Introduction

The Impulse Voltage Test System is a specialized testing equipment designed to simulate high-amplitude transient voltage conditions. In real-world scenarios, pulsed high voltages are commonly encountered in phenomena such as natural lightning strikes, where extremely high pulse currents and voltages occur at the point of impact and induce significant transient voltages in the surrounding areas. Similarly, switching operations within power systems can generate transient overvoltages with amplitudes often reaching tens to hundreds of kilovolts, posing serious risks to equipment integrity and personnel safety. To assess and mitigate these risks, experimental research on impulse voltage is essential. Moreover, simulating natural lightning phenomena provides valuable insight into discharge mechanisms and contributes to advancing electrical insulation and protection technologies.

Technical Advantages
  1. Low Inductance Circuit Design: Utilizes resistive filtering measures, enabling the generation of standard impulse waves even under large capacitive loads and high load capacity conditions.
  2. High Voltage Utilization Efficiency: Demonstrates exceptional performance with lightning impulse voltage utilization of no less than 85% and switching impulse voltage utilization exceeding 80%.
  3. User-Friendly Operation: Features simple waveform adjustment, intuitive controls, excellent synchronization performance, and reliable system operation.
  4. Advanced Charging Control: Employs constant-current charging with automated control technology, achieving a high degree of automation and strong anti-interference capability.
Equipment Maintenance
  1. To ensure personal and equipment safety, it is necessary to regularly maintain the generator. To avoid dust accumulation, the generator should be wiped regularly, especially the surfaces of the insulation platform, insulation rod, etc. should be kept clean.
  2. During operation and idle, the generator should be protected from moisture. When the surrounding air humidity is too high for a long time, the cover plate of the body should be opened; When the condensation on the inner wall of the insulation cylinder affects its use, clean hot air should be blown into each ventilation hole on the bottom to dry it.
  3. After a period of use, lubricating oil should be added to each mechanical transmission part.
  4. The semiconductor paint on the surface of the upper ceramic bushing near the middle flange of the high-voltage rectifier transformer should be well protected; If there is strong corona due to wear or failure, semiconductor anti corona paint should be sprayed to make the corona basically disappear.
  5. If there is oil leakage or abnormal noise in the components of the generator, it should be stopped from use. It can only be put back into use after repair and passing the test.
  6. If the ignition pulse system is not working properly, check whether there are short circuits or open circuits in various parts of the ignition pulse system and solve them.
500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing 0
About Sansion

Established in 2005, Sansion Power Electric comprises technical experts with over 20 years of experience in R&D, manufacturing, and marketing of power electrical testing products. Our solutions are widely applied across power electric, railroad, energy conservation and environment protection, water conservancy, petrochemical industry, aerospace, and other sectors.
Sansion Power Electric includes R&D department, instruments manufacturing workshop, HV workshop, sample exhibition room, HV testing laboratory, quality control department, general office, sales departments, and information office. We currently employ over 80 staff members, including 20 technical engineers.
We have obtained ISO9001 quality system certification, and all products strictly conform to international IEC and Chinese state standards.

500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing 1500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing 2500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing 3500kV 1kJ Lightning Impulse Voltage Generator with Full Automatic Control for Transformer Testing 4

FAQ

1. Is your company a sales company or a manufacturer?

Sansion Power Electric Co., Ltd. is an industrial and trade enterprise with its own factory, self-produced and self-sold. Founded in 2005, we have twenty years of production experience with reliable production lines, test rooms, and R&D centers.

2. Are goods in stock, can they be customized, and what is the delivery time?

Goods are made to order according to customer requirements using the latest technology. Delivery time is typically within 10 working days.

3. Is the quality guaranteed?

We use imported components and conduct three quality inspections before shipment. Export products are packed in non-fumigation wooden boxes.

4. What are the after-sales terms?

We offer free consulting service, one year warranty, and support through email communication, video calls, and on-site technical assistance to resolve after-sales problems promptly.

5. What are the cooperative countries or regions?

Products exported to United States, France, Brazil, Australia, Spain, Portugal, Oman, Russia, Netherlands, Indonesia, Bangladesh, Saudi Arabia, Chile, Colombia, Panama, Malaysia and other countries.

6. In which fields can your product be applied?

Our services span Power, Railway, Energy Conservation & Environmental Protection, Water Conservancy, Petrochemicals, and Aerospace. Our products incorporate advanced international technologies and have consistently excelled in national high-voltage testing competitions.