2026-11-17
Have you ever experienced unstable partial discharge (PD) test results, unexpected interference signals, or difficulty identifying real partial discharge activity during high-voltage testing?
These problems are more common than many testing laboratories realize.
Partial discharge measurement is extremely sensitive to electrical interference. Even relatively weak external electromagnetic signals can affect measurement results, making it difficult for engineers to distinguish actual partial discharge signals from background noise.
For transformer manufacturers, switchgear manufacturers, high-voltage equipment producers, and electrical testing laboratories, reliable PD measurement is essential for evaluating insulation performance and ensuring product quality.
So, how can these interference problems be solved?
One effective solution is to use a properly designed Partial Discharge-Free Shielded Room combined with a dedicated Partial Discharge-Free Test System.
This article explains why background noise occurs, how it affects testing accuracy, and what engineers should consider when building a reliable partial discharge testing environment.
Partial discharge is a localized electrical discharge that partially bridges the insulation between conductors. It does not completely bridge the insulation system, but it can indicate insulation defects or deterioration.
During a PD test, the measuring system detects electrical pulses generated by discharge activity.
However, the challenge is that real PD signals can be extremely weak. External electrical interference may produce signals that overlap with or resemble genuine discharge pulses.
Common sources of background interference include:
Electromagnetic interference (EMI): Signals generated by nearby electrical equipment, switching devices, and power electronics.
Power supply interference: Voltage fluctuations, harmonics, and electrical disturbances from the power network.
Radio-frequency interference: Signals from wireless communication devices, radio transmitters, and other electronic equipment.
Grounding problems: Improper grounding connections and ground loops can introduce unwanted electrical noise.
Poor testing environments: Inadequate shielding, cable arrangements, and equipment layouts can increase interference.
When these factors are not properly controlled, engineers may encounter unstable readings, false discharge indications, or difficulty determining the actual PD inception level.
For manufacturers and testing laboratories, excessive background noise is not simply a measurement inconvenience. It can directly affect daily testing operations.
When interference signals overlap with real PD signals, it becomes more difficult to evaluate the actual insulation condition of the test object.
This may lead to uncertain test conclusions and repeated measurements.
Engineers need to distinguish genuine discharge activity from external interference.
If the background noise level is too high, identifying the source of individual signals becomes much more complicated.
Unstable measurement results may require additional testing, troubleshooting, and equipment adjustments.
For manufacturers with frequent production inspections, these repeated procedures can reduce testing efficiency and increase operating costs.
A noisy testing environment makes it harder to maintain consistent measurement conditions, especially when different products need to be tested throughout the working day.
A Partial Discharge-Free Shielded Room is designed to provide a controlled electromagnetic environment for high-sensitivity partial discharge measurements.
Its main purpose is to reduce external electromagnetic interference entering the testing area.
A properly engineered shielded room typically incorporates several important design elements:
1. Electromagnetic Shielding Structure
The shielding enclosure helps attenuate external electromagnetic signals that may interfere with sensitive PD measurements.
The shielding effectiveness should be designed according to the required testing frequency range and measurement sensitivity.
2. Proper Grounding Design
A well-planned grounding system helps control unwanted electrical interference and provides appropriate grounding connections for the shielded enclosure and testing equipment.
3. Shielded Cable and Signal Connections
Suitable shielded cables, connectors, and cable routing help reduce interference entering the measurement circuit.
4. Filtered Power Supply Connections
Appropriate power-line filtering can help reduce conducted electrical interference entering the testing environment.
5. Controlled Equipment Layout
Separating high-voltage equipment, measuring instruments, and auxiliary electrical devices according to the system design can help minimize unwanted coupling and interference.
It is important to understand that a shielded room does not automatically eliminate every source of noise. The complete installation, grounding arrangement, equipment configuration, and testing procedures must work together.
A shielded room and a partial discharge measuring system perform different but complementary functions.
The shielded room helps control the external electromagnetic environment, while the PD test system generates the required test voltage, detects discharge signals, and supports measurement and analysis.
A complete Partial Discharge-Free Shielded Room + Partial Discharge-Free Test System can provide an integrated testing solution.
Key advantages include:
Improved measurement conditions: Reduced external interference helps create a more stable environment for sensitive PD measurements.
Reliable signal acquisition: A properly configured measurement system helps detect and analyze partial discharge signals.
Better testing consistency: Controlled test conditions support repeatable testing procedures.
Improved laboratory efficiency: An integrated solution can simplify equipment arrangement and testing operations.
Flexible testing applications: The system can be configured according to different high-voltage equipment and laboratory requirements.
A low-interference testing environment is particularly important for industries that manufacture or inspect high-voltage electrical equipment.
Typical applications include:
Power Transformer Manufacturers: Partial discharge testing helps evaluate the insulation condition of power transformers and related components.
Switchgear Manufacturers: PD measurement can help assess insulation performance in medium- and high-voltage switchgear.
High-Voltage Cable Manufacturers: Partial discharge testing is used to evaluate insulation quality in high-voltage cable systems and accessories.
GIS Manufacturers: PD testing supports insulation assessment in gas-insulated switchgear.
Electrical Testing Laboratories: A controlled testing environment helps laboratories perform sensitive electrical measurements.
Research and Development Centers: Low-interference environments support insulation research and high-voltage testing experiments.
Before investing in a partial discharge testing facility, engineers and procurement teams should evaluate several important factors.
| Evaluation Item | What to Check |
|---|---|
| Shielding Effectiveness | Attenuation performance across the required frequency range |
| Background Noise Level | Whether the environment meets the target PD measurement requirements |
| Testing Voltage | Required AC, DC, or other test voltage configurations |
| Test Object Dimensions | Maximum size and weight of the equipment to be tested |
| Measurement Sensitivity | Required apparent charge measurement range and resolution |
| Grounding System | Grounding design and electrical safety |
| System Integration | Compatibility between the shielded room, HV source, and PD measuring equipment |
| Future Expansion | Possibility of adding test equipment or supporting different applications |
One particularly important point is to define the acceptable background noise level before purchasing.
A supplier should be able to explain the measurement conditions, test methods, and verification results used to demonstrate the shielding room's performance.
Uncontrolled electromagnetic interference can make partial discharge testing difficult, time-consuming, and less reliable.
For manufacturers and testing laboratories that require sensitive insulation measurements, a properly designed PD-Free Shielded Room combined with a dedicated PD Test System offers a practical way to improve the testing environment and support more consistent measurement results.
Looking for a Partial Discharge-Free Shielded Room and Test System for your laboratory or manufacturing facility?
Sansion provides integrated high-voltage testing equipment solutions designed around different customer testing requirements.
Contact our engineering team to discuss your test voltage, test object dimensions, required measurement sensitivity, and laboratory layout. We can help you identify a suitable testing configuration for your application.